Skip to Content

Inverters

Technical selection for professionals

How to choose a solar inverter for a professional project

Choosing a solar inverter takes more than comparing kW. Check single-phase or three-phase connection, grid voltage, AC power, DC/AC ratio, each MPPT range and current, string design, grid code and communications. For hybrid models, also verify the battery, BMS, firmware, metering and backup.

Over 20 years of experienceProfessional distributionSelection and commissioning support
Lynx Distributor (M8)
Distribuitor Lynx (M8)
Only 1 Units left in stock.
Sigenergy Sigen Gateway C300-12 (300kW) (11110010)
Sigen Gateway HomeMax TP (Three-phase) for 12 inverters

• 3 circuit breaker positions reserved for SigenStor or other loads
• 0ms switch to backup mode, worry-free power usage
• Ready for generator, heat pump or other controllable loads
• Supports whole home backups and partial home backups
• 350 ms reverse power flow protection of grid and generator
• Uninterrupted power supply through PV+ESS/grid/generator
Fuse holder for MEGA-fuse
Fuse holder for MEGA-fuse.

Llega en 1 semana!

Multiplus-II 48/5000/70-50 230V (5kWn)
5000VA 48V 230V IP22 (Includes 70A charger)
Only 1 Units left in stock.
Only 10 Units left in stock.
Interface MK3-USB
Use the MK3-USB to connect the following products to a computer for configuration: Multi, MultiGrid, MultiPlus, MultiPlus-II, Quattro, Inverter (only models with VE.Bus communication port), ECOmulti, EasySolar, EasyPlus.
Only 2 Units left in stock.
Sigenergy Sigen PV Inverter 110M1-HYA (110kWn) (11010135)
• Rated AC output power: 110 kW (380/400 V, 50/60 Hz)
• Number of MPPT: 8 independent inputs
• MPPT input voltage range: 160–1000 V
• Maximum efficiency: 98.3%
Only 3 Units left in stock.
Sigenergy Sigen Hybrid 3.0 SP2 (3kWn) (11020005)
• 3 kW single-phase hybrid inverter: Ideal for medium-sized homes or autonomous systems
• Full integration: Compatible with solar panels, SigenStor batteries and generators
• Automatic backup: Instant (0 ms) switch to backup mode for critical loads
• Robust design: Metal casing, no fans, silent operation (≤25 dB)
Only 2 Units left in stock.
Sigenergy Sigen Hybrid 5.0 TP2 (5kWn) (11010182)
● Compact and silent design (25 dB)
● 2 MPPT with high efficiency and flexibility
● IP66 protection and wide thermal range
● Compatible with SigenStor batteries and smart integration
Only 2 Units left in stock.
MEGA-FUSE 250A/58V for 48V 1 unit
The Victron MEGA-Fuse 250A/58V fuse has been designed for isolated photovoltaic installations.
It is compatible with Victron's MEGA fuse holders, with installations of 48 and with a maximum supported intensity of 250A.
Sigenergy Sigen PV Inverter 125M1-HYA (125kWn) (11010136)
• Rated AC output power: 125kW (400V, 50/60Hz)
• Number of MPPT: 8 independent inputs (2 chains per MPPT)
• MPPT input voltage range: 160–1000V
• Maximum efficiency: 98.6%
Only 9 Units left in stock.
Sigenergy Sigen Hybrid 6.0 TP2 (6kWn) (11010183)
• Rated AC output power: 6 kW (380/400 V, 50/60 Hz)
• Number of MPPT: 2 independent inputs
• MPPT input voltage range: 160–1000 V
• Maximum efficiency: 98.6%
Only 6 Units left in stock.
Sigenergy Sigen PV Inverter 50M1-HYA (50kWn) (11010131)
• Rated AC output power: 50kW (400V, 50Hz)
• Number of MPPT: 4 independent inputs (2 chains per MPPT)
• MPPT input voltage range: 160–1000V
• Maximum efficiency: 98.6%
Sigenergy Sigen PV Inverter 60M1-HYA (60kWn) (11010132)
• Rated AC output power: 60kW (400V, 50Hz)
• Number of MPPT: 5 independent inputs (2 chains per MPPT)
• MPPT input voltage range: 160–1000V
• Maximum efficiency: 98.6%
Only 5 Units left in stock.
Sigenergy Sigen Hybrid 8.0 TP2 (8kWn) (11010184)
• Rated AC output power: 8 kVA (380/400 V, 50/60 Hz)
• Number of MPPT: 2 independent inputs
• MPPT input voltage range: 160–1000 V
• Maximum efficiency: 98.6%
Multiplus-II 48/3000/35-32 230V (3kWn)
3000VA 48V 230V IP22 (Includes 35A charger)
Only 2 Units left in stock.
Sigenergy Sigen PV Inverter 100M1 (100kWn - Non-Hybrid) (11010071)
Sigen PV Inverter
Models: 50M1, 60M1, 80M1, 100M1, 110M1

DC input
Max photovoltaic energy CC: 90,000 - 198,000 Wp
Max voltage DC input: 1,100 V
MPPT number: 4 - 8 (depending on model)
Protection

Safety Protection Function: Includes arc fault circuit breaker, DC reverse polarity protection, residual current monitoring, DC/AC type II surge protection, islanding protection, insulation monitoring, and AC overcurrent/overvoltage/short circuit protection.
General data

Measurements (width × height × depth): 918 / 640 / 340 mm
Weight: 68 - 75kg
Operating temperature range: -30 ~ 60 °C
IP protection grade: IP66
Communication: WLAN / Fast Ethernet / RS485 / Sigen CommMod (4G/3G/2G)
Only 7 Units left in stock.
Sigenergy Sigen Gateway C180-9 (180kW) (11110026)
• High capacity: Supports up to 9 inverters.
• Storage Compatible: Works with SigenStor, generators and EVs.
• Security: Reverse flow 350 ms and backup 0 ms.
• Uninterrupted power: Continuous supply via PV + ESS / grid / generator.
VE.DIRECT TO USB INTERFACE
Interface to connect Victron products to the computer.
Only 3 Units left in stock.
Sigenergy Sigen PV Inverter 80M1-HYA (80kWn) (11010133)
• Rated AC output power: 80kW (400V, 50Hz)
• Number of MPPT: 6 independent inputs (2 chains per MPPT)
• MPPT input voltage range: 160–1000V
• Maximum efficiency: 98.6%
Only 1 Units left in stock.
Decision guide

Which inverter fits the project

ApplicationMain criteriaCritical checks
ApplicationResidential grid-connected PVMain criteriaPhases, AC power, MPPT, start voltage, input current and monitoring.Critical checksString Voc and Isc, minimum temperature, DC/AC ratio, protection and grid code.
ApplicationHybrid with batteryMain criteriaAll of the above plus battery range, charge/discharge power, metering and backup.Critical checksDocumented compatibility between inverter, battery and BMS, firmware and critical loads.
ApplicationC&I and large rooftopsMain criteriaPower, multiple MPPTs, string current, operating efficiency, communications and control.Critical checksAC board, DC/AC protection, grid, export, monitoring and environmental conditions.
ApplicationRevamping an existing plantMain criteriaAdaptation to the existing PV array and AC connection without assuming a direct replacement.Critical checksStrings, insulation, protection, transformer, communications, regulations and outage strategy.

What is the difference between a hybrid and a grid inverter?

A hybrid manages a compatible battery and, depending on the architecture, backup. A grid inverter converts PV generation for consumption or export. Exact functions depend on the model and complete system.

How is inverter power selected?

Use PV array power and orientation, connection, grid limits, load profile, DC/AC ratio and temperature conditions. Do not select it only from total module nameplate power.

Can any current model replace an old inverter?

No. Check Voc, Isc, string current and count, MPPTs, AC connection, protection, communications, any transformer and grid requirements. Revamping requires a specific assessment.

Can any battery connect to a hybrid inverter?

No. DC compatibility requires documented matching of models, voltage, BMS and firmware. An AC-coupled battery may coexist electrically, but this does not mean direct DC-port compatibility or universal functional integration.

Validate the model before finalising the quote

We help review the PV array, grid, MPPT, battery, communications and commissioning.

Updated 11 September 2026. Final selection is validated against current documentation and real project data.

WhatsApp