Skip to Content

Inverters

Technical selection for professionals

How to choose a solar inverter for a professional project

Choosing a solar inverter takes more than comparing kW. Check single-phase or three-phase connection, grid voltage, AC power, DC/AC ratio, each MPPT range and current, string design, grid code and communications. For hybrid models, also verify the battery, BMS, firmware, metering and backup.

Over 20 years of experienceProfessional distributionSelection and commissioning support
No results found for 'Siguen'. Showing results for 'sigen'.
Sigenergy SigenStor EC 25 TP (25kWn) (11010018)
25kw Three Phase Hybrid Inverter - 4MPPT

Max. input voltage: 1100V
Max. Rated input voltage: 600V
Max. intensity per MPPT: 16A
Maximum efficiency:98.4%
Protection: IP66
10 year warranty
Sigenergy SigenStor EC 6.0 SP (6kWn) (11040001)
• 6 kW - 2 MPPT single-phase hybrid inverter
• Max. input voltage: 600V
• Max. Rated input voltage: 350V
• Maximum efficiency: 98%
• Protection: IP66
Sigenergy Sigen Gateway HomePro TP 30kW (11110031)
• Immediate backup: 0 ms changeover and continuous supply via PV + ESS / grid / generator
• Compatible with loads and SigenStor: Up to 30 kW and controllable devices (generator, heat pump)
• Advanced protection: Reverse flow 350 ms for network and generator
• Power Connections: Supports up to 100 A AC input, 32 A inverter and optional 14.5 kW generator/load
Sigenergy Sigen Hybrid 6.0 SP2 (6kWn) (11020010)
• Rated AC output power: 6 kW (220/230/240 V, 50/60 Hz)
• Number of MPPT: 2 independent inputs
• MPPT input voltage range: 160–1000 V
• Maximum efficiency: 98.6%
Sigenergy SigenStor EC 20 TP (20kWn) (11010017)
20kw three-phase hybrid inverter - 4MPPT

Max. input voltage: 1100V
Max. Rated input voltage: 600V
Max. intensity per MPPT: 16A
Maximum efficiency:98.4%
Protection: IP66
10 year warranty
Only 5 Units left in stock.
Sigenergy Sigen Gateway HomePro SP (11110056)
• Immediate backup: 0 ms changeover and continuous supply via PV + ESS / grid / generator
• Compatible with loads and SigenStor: Up to 12 kW and controllable devices (generator, heat pump)
• Advanced protection: Reverse flow 350 ms for network and generator
• Power connections: Supports up to 100 A in AC input, 32 A inverter and optional 14.5 kW generator/load
Sigenergy SigenStor EC 15 TP (15kWn) (11010015)
• 15kW three-phase hybrid inverter: 3 MPPT.
• Max. Input voltage: 1100V.
• Maximum efficiency: 98.4%.
• Protection: IP66, resistant to dust and water.
Sigenergy SigenStor EC 10.0 SP (10kWn) (11040028)
• 10kW single-phase hybrid inverter: 4 MPPT.
• Max. input voltage: 600V.
• Max. Rated input voltage: 350V.
• Maximum efficiency: 98%.
• Protection: IP66, resistant to dust and water.
Sigenergy SigenStor EC 10.0 TP (10kWn) (11010013)
• 10kW three-phase hybrid inverter: 3 MPPT.
• Max. Input voltage: 1100V.
• Max. Rated input voltage: 600V.
• Maximum efficiency: 98.4%.
• Protection: IP66, resistant to dust and water.
Sigenergy SigenStor EC 8.0 SP (8kWn) (11040029)
• 8 kW - 3 MPPT single-phase hybrid inverter
• Max. input voltage: 600V
• Max. Rated input voltage: 350V
• Maximum efficiency: 98%
• Protection: IP66
Only 3 Units left in stock.
Sigenergy SigenStor EC 5.0 SP (5kWn) (11040002)
• 5 kW - 2 MPPT single-phase hybrid inverter
• Max. Input voltage: 1100V
• Max. Rated input voltage: 600V
• Maximum efficiency: 98%
• Protection: IP66
Sigenergy Sigen PV Inverter 100M1-HYA (100kWn) (11010134)
• Rated AC output power: 100 kW (380/400 V, 50/60 Hz)
• Number of MPPT: 8 independent inputs
• MPPT input voltage range: 160–1000 V
• Maximum efficiency: 98.3%
Only 10 Units left in stock.
Sigenergy Sigen Gateway C120-6 (118-124kW) (11110009)
• 3 circuit breaker positions reserved for SigenStor or other loads
• 0ms switch to backup mode, worry-free power usage
• 350 ms reverse power flow protection of grid and generator
• Uninterrupted power supply through PV+ESS/grid/generator
Only 7 Units left in stock.
Sigenergy SigenStor EC 8.0 TP (8kWn) (11010012)
• 8 kW three-phase hybrid inverter - 2 MPPT
• Max. Input voltage: 1100V
• Max. Rated input voltage: 600V
• Maximum efficiency: 98.4%
• Protection: IP66
Sigenergy SigenStor EC 17 TP (17kWn) (11010016)
17kw Hybrid Three Phase Inverter - 4MPPT

Max. input voltage: 1100V
Max. Rated input voltage: 600V
Max. intensity per MPPT: 16A
Maximum efficiency:98.4%
Protection: IP66
10 year warranty
Only 7 Units left in stock.
Sigenergy Sigen Hybrid 5.0 SP2 (5kWn) (11020009)
• 5 kW single-phase hybrid inverter: Ideal for medium-sized homes or autonomous systems
• Full integration: Compatible with solar panels, SigenStor batteries and generators
• Automatic backup: Instant (0 ms) switch to backup mode for critical loads
• Robust design: Metal casing, no fans, silent operation (≤25 dB)
Sigenergy Sigen Power Sensor Single Phase External CT 100 A (14370005)
• Maximum precision of 1% in power measurement for exact control of consumption, generation and energy optimization
• Plug & play integration with Sigenergy systems via Modbus, without additional configuration
• Real-time monitoring with data refresh every 100ms for instant response
• Versatile installation: direct connection up to 100A or with external current transformers (CT)
Sigenergy Sigen Power Sensor TP-DH-Indirecto External CT 600 A DH (1426000300)
Sigen Power Sensor integrates seamlessly with Sigenergy devices, with no configuration required.
This power sensor is part of SigenStor's 5-in-1 energy storage system.
Sigenergy's ESS seamlessly integrates the PV inverter, battery power conversion system (PCS), EV DC charger for electric vehicles, battery pack and energy management system (EMS).
Sigenergy Sigen Power Sensor TP-CT120-DH (medida indirecta) (1426000007)
Sigen Power Sensor integrates seamlessly with Sigenergy devices, with no configuration required.
This power sensor is part of SigenStor's 5-in-1 energy storage system.
Sigenergy's ESS seamlessly integrates PV inverter, battery power conversion system (PCS), DC EV charger for electric vehicles, battery pack and energy management system (EMS).
Sigenergy Sigen Power Sensor 1PH- Single Phase Direct (1426000004)
• 1% accuracy in power detection for exact control
• 100A single-phase direct connection with built-in CT
• Modbus RTU communication via RS485
• Supports export/import limitations and prepared for AI evolution
Decision guide

Which inverter fits the project

ApplicationMain criteriaCritical checks
ApplicationResidential grid-connected PVMain criteriaPhases, AC power, MPPT, start voltage, input current and monitoring.Critical checksString Voc and Isc, minimum temperature, DC/AC ratio, protection and grid code.
ApplicationHybrid with batteryMain criteriaAll of the above plus battery range, charge/discharge power, metering and backup.Critical checksDocumented compatibility between inverter, battery and BMS, firmware and critical loads.
ApplicationC&I and large rooftopsMain criteriaPower, multiple MPPTs, string current, operating efficiency, communications and control.Critical checksAC board, DC/AC protection, grid, export, monitoring and environmental conditions.
ApplicationRevamping an existing plantMain criteriaAdaptation to the existing PV array and AC connection without assuming a direct replacement.Critical checksStrings, insulation, protection, transformer, communications, regulations and outage strategy.

What is the difference between a hybrid and a grid inverter?

A hybrid manages a compatible battery and, depending on the architecture, backup. A grid inverter converts PV generation for consumption or export. Exact functions depend on the model and complete system.

How is inverter power selected?

Use PV array power and orientation, connection, grid limits, load profile, DC/AC ratio and temperature conditions. Do not select it only from total module nameplate power.

Can any current model replace an old inverter?

No. Check Voc, Isc, string current and count, MPPTs, AC connection, protection, communications, any transformer and grid requirements. Revamping requires a specific assessment.

Can any battery connect to a hybrid inverter?

No. DC compatibility requires documented matching of models, voltage, BMS and firmware. An AC-coupled battery may coexist electrically, but this does not mean direct DC-port compatibility or universal functional integration.

Validate the model before finalising the quote

We help review the PV array, grid, MPPT, battery, communications and commissioning.

Updated 11 September 2026. Final selection is validated against current documentation and real project data.

WhatsApp