Skip to Content

Inverters

Technical selection for professionals

How to choose a solar inverter for a professional project

Choosing a solar inverter takes more than comparing kW. Check single-phase or three-phase connection, grid voltage, AC power, DC/AC ratio, each MPPT range and current, string design, grid code and communications. For hybrid models, also verify the battery, BMS, firmware, metering and backup.

Over 20 years of experienceProfessional distributionSelection and commissioning support
No results found for 'Siguen'. Showing results for 'sigen'.
Sigenergy Sigen Gateway C180-9 (180kW) (11110026)
• High capacity: Supports up to 9 inverters.
• Storage Compatible: Works with SigenStor, generators and EVs.
• Security: Reverse flow 350 ms and backup 0 ms.
• Uninterrupted power: Continuous supply via PV + ESS / grid / generator.
Sigenergy Sigen PV Inverter 80M1-HYA (80kWn) (11010133)
• Rated AC output power: 80kW (400V, 50Hz)
• Number of MPPT: 6 independent inputs (2 chains per MPPT)
• MPPT input voltage range: 160–1000V
• Maximum efficiency: 98.6%
Only 3 Units left in stock.
Sigenergy Sigen Gateway C600-30 (600kW) (11110027)
Sigen Energy Gateway C&I 600 kW

Compatible with up to 30 SigenStor inverters connected in parallel
3 circuit breaker positions reserved for SigenStor or other loads
0 ms switch to backup mode for uninterrupted power use
Prepared for connection of generator, heat pump or other controllable loads
350 ms anti-reverse protection against mains and generator
Uninterrupted power supply via PV + ESS/grid/generator
Only 1 Units left in stock.
Sigenergy Sigen Gateway C1200-50 (1200kW) (11110025)
• High capacity: Up to 50 kW and 50 inverters.
• Storage Compatible: Works with SigenStor, generators and EVs.
• Security: Reverse flow 350 ms and backup 0 ms.
• Uninterrupted Power: Supply through PV + ESS / grid / generator.
Only 1 Units left in stock.
Sigenergy Sigen Hybrid 2.0 SP2 (2kWn) (11020004)
• Compact hybrid inverter: Nominal power of 2 kW, ideal for small homes or autonomous systems
• Flexible integration: Compatible with solar panels, batteries and external generators
• Automatic backup: Instant (0 ms) switch to backup mode for critical loads
• Robust design: Slim metal case, no fans, quiet operation (≤25 dB)
Only 5 Units left in stock.
Sigenergy Sigen Hybrid 4.0 TP2 (4kWn) (11010181)
• 4 kW three-phase hybrid inverter: Ideal for medium-sized homes or autonomous systems
• Full integration: Compatible with solar panels, SigenStor batteries and generators
• Automatic backup: Instant (0 ms) switch to backup mode for critical loads
• Robust design: Metal casing, no fans, silent operation (≤25 dB)
Sigenergy Sigen Gateway C1200 for HYB - Sigenstack (11110054)
• Compatible with multiple Sigen C&I inverter connections for microgrid systems.
• Seamless switching, ensuring 0 ms interruption on the load side.
• Integrated bypass circuit for greater system reliability.
• Compatible with the connection of diesel generators and intelligent control.
• Real-time current monitoring with 350 ms backflow protection.
Only 2 Units left in stock.
Sigenergy Sigen Hybrid 3.0 TP2 (3kWn) (11010180)
• 3 kW three-phase hybrid inverter: Ideal for homes and small commercial facilities
• Full integration: Compatible with solar panels, SigenStor batteries and generators
• Automatic backup: Instant (0 ms) switch to backup mode for critical loads
• Robust design: Metal casing, no fans, silent operation (≤25 dB)
Only 6 Units left in stock.
Sigenergy Sigen Gateway C600-B (for HYB series) (11110053)
Sigen Gateway C600 for HYB
Supports multiple SigenStor connections for microgrid systems
Seamless backup, worry-free power usage for your business
Generator support, more abundant backup power
350ms standby power flow protection for grid and generator
Uninterrupted power supply through PV+ESS/grid/generator
Only 4 Units left in stock.
Sigenergy Sigen Gateway C1600-B-MN - Sigenstack (conexión a red y cargas críticas) (11110065)
Three-phase power: 1.6 MW
Instant backup (0 ms)
Supports up to 30 SigenStor batteries
Reverse flow protection (350 ms)
Sigenergy Sigen Gateway C1600-B-ST - Sigenstack (Smart Load Cabinet) (11110066)
Intelligent load distribution and backup cabinet
Manage critical and non-critical loads automatically
Instant changeover (0 ms) in case of blackout
Up to 60 kW capacity in smart charging
Sigenergy Sigen Gateway B-INV-15 (connection up to 15 inverters) (11110063)
Sigen Energy Gateway HYB-15 Inverter Connection
Cabinet
Sigenergy EWS-5Y INV SP2 2-6 – 5-year warranty extension Sigen Hybrid SP2 (2–6 kW) (41010066)
EWS-5Y INV SP2 2-6 – 5-year warranty extension Sigen Hybrid SP2 (2–6kW) (41010066)
Sigenergy EWS-5Y INV TP2 3-12 – Warranty extension 5 years Sigen Hybrid TP2 (3–12 kW) (41010067)
EWS-5Y INV TP2 3-12 – 5-year warranty extension Sigen Hybrid TP2 (3–12kW) (41010067)
Sigenergy Sigen Gateway C2400-B-MN- Sigenstack (conexión a red y cargas críticas) (11110061)
Supports multiple Sigen C&I inverter connections for microgrid systems
Seamless switching, guaranteeing 0 ms cut-off on the load side
Integrated bypass circuit for increased system reliability
Compatible with connection to diesel generator and intelligent control
Real-time current monitoring with 350 ms anti-reverse protection
Sigenergy Sigen Gateway HomePro SP-F 24kW (11110030)
• Immediate backup: 0 ms changeover and continuous supply via PV + ESS / grid / generator
• Compatible with loads and SigenStor: Up to 24 kW and controllable devices (generator, heat pump)
• Advanced protection: Reverse flow 350 ms for network and generator
• Power connections: Supports up to 100 A in AC input, 32 A inverter and optional 14.5 kW generator/load
Sigenergy Sigen Hybrid 3.6 SP2 (3.6kWn) (11020006)
• 3.6 kW single-phase hybrid inverter: Ideal for medium-sized homes or autonomous systems
• Full integration: Compatible with solar panels, SigenStor batteries and generators
• Automatic backup: Instant (0 ms) switch to backup mode for critical loads
• Robust design: Metal casing, no fans, silent operation (≤25 dB)
Decision guide

Which inverter fits the project

ApplicationMain criteriaCritical checks
ApplicationResidential grid-connected PVMain criteriaPhases, AC power, MPPT, start voltage, input current and monitoring.Critical checksString Voc and Isc, minimum temperature, DC/AC ratio, protection and grid code.
ApplicationHybrid with batteryMain criteriaAll of the above plus battery range, charge/discharge power, metering and backup.Critical checksDocumented compatibility between inverter, battery and BMS, firmware and critical loads.
ApplicationC&I and large rooftopsMain criteriaPower, multiple MPPTs, string current, operating efficiency, communications and control.Critical checksAC board, DC/AC protection, grid, export, monitoring and environmental conditions.
ApplicationRevamping an existing plantMain criteriaAdaptation to the existing PV array and AC connection without assuming a direct replacement.Critical checksStrings, insulation, protection, transformer, communications, regulations and outage strategy.

What is the difference between a hybrid and a grid inverter?

A hybrid manages a compatible battery and, depending on the architecture, backup. A grid inverter converts PV generation for consumption or export. Exact functions depend on the model and complete system.

How is inverter power selected?

Use PV array power and orientation, connection, grid limits, load profile, DC/AC ratio and temperature conditions. Do not select it only from total module nameplate power.

Can any current model replace an old inverter?

No. Check Voc, Isc, string current and count, MPPTs, AC connection, protection, communications, any transformer and grid requirements. Revamping requires a specific assessment.

Can any battery connect to a hybrid inverter?

No. DC compatibility requires documented matching of models, voltage, BMS and firmware. An AC-coupled battery may coexist electrically, but this does not mean direct DC-port compatibility or universal functional integration.

Validate the model before finalising the quote

We help review the PV array, grid, MPPT, battery, communications and commissioning.

Updated 11 September 2026. Final selection is validated against current documentation and real project data.

WhatsApp