For homes and small professional projects.
SMA SHP 100-20 HIGHPOWER PEAK3 (100kWn - 400VAC)
SMA P&P0081Equipo compacto para sistemas descentralizados y sistemas fotovoltaicos a gran escala por su alta densidad de potencia. “Active cooling” con ventiladores controlados por velocidad, aseguran una óptima refrigeración con menor consumo energético, maximiza la producción por reducción de temperatura Tecnología de 2400V, con 2 stacks de potencia de 1200V en serie Potencia máx. del generador FV: 150000 wp Tensión de entrada máx. 1000V Corriente de entrada máx./Corriente de cortocircuito máx: 180 A/325 A Número de seguidores del MPP: 1 Certificado para España y Portugal Garantía 5 años
| Power (Wn): 100 K |
| singlephase/threephase: Trifásico |
| Function: No híbrido |
| MPPT voltage range (V): 590-1000 |
| Marca: SMA |
| warranty: 5 años |
Documents
Compatibility and configuration
Official data for SMA Sunny Highpower SHP 100-20: technical values for the documented model; the existing commercial name states SHP 100-21
Documented model
SHP 100-20
Maximum PV power
150 kWp
Maximum input
1.000 Vcc
MPP range
590-1.000 V
Power
100 kW · rated AC
Voltage
400 Vac · 304-477 V range
Current
151 A · maximum output
Efficiency
98.8% max. · 98.6% European
Protection
IP65
Technical frequently asked questions
What is its function?
It converts PV energy into three-phase AC for decentralized industrial plants.
Which system is it compatible with?
The attached sheet documents SHP 100-20; confirm equivalence with the SHP 100-21 commercial suffix.
What must be checked before installation?
Check exact model, DC and AC voltage, MPP range, power, protection, cooling and grid code.
Official source published on this product page: data sheet. Specifications are subject to the conditions in the linked document. The source does not publish an unambiguous weight for this reference; Product.weight is omitted.
Add Atmoce storage without replacing this inverter
In grid-connected installations with a compatible architecture, Atmoce storage can be added on the AC side.
Important: The integration is AC-coupled: it does not imply connection to the battery port or direct DC compatibility. Phases, metering/EMS, backup, protection and system topology must be validated before quoting.